Solution Of Diesel Generator Glitch!

图片
  Solution Of Diesel Generator Glitch! Radiator tubes leakage When the diesel generator is working, the internal water temperature of the radiator is too high and the external temperature is too low. Or due to the vibration of the diesel generator, it is easy to cause the radiator pipe leakage. In case of leakage, loose tobacco can be put into the radiator, and the pressure of water circulation can be used to block the tobacco in the leaking part for temporary use. If the radiator pipe leaks seriously, you can cut off the leakage, then apply the cotton ball to the cut radiator pipe, then use pliers to flatten the head of the cut radiator pipe, and then curl it. Press firmly to prevent water leakage. Water pump leakage When aluminum water pump is used in diesel generator, sometimes the seal is not tight.. The water seal surface shall be polished flat or turned 180 ° before installation and use. If the thrust rubber ring is damaged, expanded, deformed, or the spring i...

Diesel Generator Exhaust Noise

图片
  Diesel Generator Exhaust Noise The most effective way to control exhaust noise is to install muffler, but the noise reduction effect is poor. The main reasons are unreasonable structure and problems in processing technology. Technical problems can be improved by improving the process. The design idea of muffler is mainly based on experience, and some design calculations are carried out under ideal assumptions. In these assumptions, the biggest impact is to ignore the air flow regeneration noise, which will affect the pipes, shells, partitions and other components of the muffler, and then excite the vibration radiation noise. When the muffler structure parameters are unreasonable, the structure is unreasonable or the processing technology has problems, the muffler performance will be reduced. At the same time, too high air flow rate will increase the pressure loss of the muffler, resulting in a decline in the performance of the muffler. Get more Diesel Generator Part...

Generator Radiator Water Temperature

图片
  Generator Radiator Water Temperature The water temperature of the generator has clear regulations, but some people want to adjust the outlet water temperature very low, even close to the lower limit. They believe that the water temperature is low, there will be no air erosion in the pump, and the cooling water or liquid will not be interrupted, which is guaranteed. In fact, as long as the water temperature does not exceed 95 ° C, air erosion will not occur, and the cooling water or liquid will not be interrupted. Otherwise, if the water temperature is too low, it will be extremely detrimental to the operation of the generator. 1.If the temperature is low, the combustion in the cylinder will deteriorate, the fuel atomization will be poor, the combustion time will be prolonged after the fire, the engine operation will be unstable, the damage of crankshaft bearings, piston rings and other components will be aggravated, and the power and economy will be reduced. 2.The w...